Satsuki Okumura
;
Yutaka Terao
;
Hiroyuki Ohsaki
;
Akihiro Kikuchi
説明:
(abstract)In this paper, the authors performed a numerical analysis of AC loss when a rotating magnetic field was applied to the MgB2 wire. The H-φ formulation was used for the finite element analysis. AC losses include coupling losses, hysteresis losses, and eddy current losses. The AC losses were calculated when the contact resistivity and contact length were changed. The rotational frequencies were 25 Hz and 50 Hz, and the maximum magnetic flux density amplitude was 0.01 T. As a result, it was revealed that the coupling loss was inversely proportional to the contact resistance. It was also revealed that the coupling loss was proportional to the square of the contact length. These trends can be understood from the theoretical formula for coupling loss.
権利情報:
キーワード: MgB2 wire, rotating magnetic field, three-dimensional FEM analysis, AC loss, coupling loss
刊行年月日: 2025-01-10
出版者: Institute of Electrical and Electronics Engineers (IEEE)
掲載誌:
研究助成金:
原稿種別: 著者最終稿 (Accepted manuscript)
MDR DOI: https://doi.org/10.48505/nims.5593
公開URL: https://doi.org/10.1109/tasc.2025.3527950
関連資料:
その他の識別子:
連絡先:
更新時刻: 2025-07-16 16:30:32 +0900
MDRでの公開時刻: 2025-07-16 16:18:21 +0900